Proton
Exchange Membrane Fuel Cell
Overview
Current/Completed Plug Power activities list
- Testing of natural gas SU-1
- Display of natural gas SU-1 (plexi-glass panels)
- Testing of natural gas GenSys-5
- Use of GenCore to test reformate quality effects using a novel cyclic
autothermal reformer from GE
- Use of GenCore to investigate effects of fuel quality and dynamic
changes in fuel composition and flow on performance
- Dynamic simulation of the GenSys and GenCore systems
- Support of sales team when asked (show operating units, discuss technology,
objective perspective)
- Worked as partner to garner SCAQMD funding for fuel cell testing
GenCore system is sensitive to diluents
- As built design includes exhaust gas recirculation and a vent flow for removing small amounts of fuel contaminants
UCI System Modifications: •
Anode exhaust gas recirculation (EGR) system eliminated
•- Dead-headed anode was transformed to an
anode with a straight-through
flow path- Mechanism for venting only 0.05% impurities not sufficient
- Leads to a buildup of impurities in the anode
- Humidification was added to simulated fuel stream to compensate
for
removal of EGR - Functionality of the modified GenCore Fuel Cell system was tested
- H2 operation repeated to determine baseline operability with modifications
- Diluents (CO2, CO, CH4) added to H2 stream as “proof of concept” of straight-through anode
- Flow rates were determined based on 33-50% utilization for all operating condition
GenCore Testing with ACR
| Low | High | |
|---|---|---|
| Hydrogen | 70% |
100% |
| CO2 | 25% |
30% |
| C0 | 0 ppm |
10 ppm |
| CH4 | 0% |
2.40% |
| % | Flow | |
|---|---|---|
| Hydrogen | 74% |
70 slpm |
| CO | 10 ppm |
0.65 sccm |
| CH4 | 1% |
0.937 slpm |
| CO2 | balance |

GenCore Performance with Straight-Through Anode



Summary – GenCore Testing with ACR
- Unmodified GenCore Fuel Cell system cannot be operated on a fuel
with an impurity level over the design limit (99.95% H2)
- Modified GenCore Fuel Cell system with straight-through anode can
be operated on reformate fuels
- CO Poisoning effect on fuel cell anode is still a vital issue to
be addressed and investigated
- But measured performance with 10 ppm < [CO] < 100ppm
showed no long-term degraded performance
- But measured performance with 10 ppm < [CO] < 100ppm
showed no long-term degraded performance
- Integration of GenCore Fuel Cell system with the GEGR ACR system was a success (although reformer never met desired fuel specifications)
Dynamic Model of GenSys System












Personnel
Investigators: Prof. Jack Brouwer, UCI
Prof. Kyoung Doug Min, Seoul National University
Students: Fabian Mueller, Graduate Student Researcher, UCI
Sang Kyu Kang, Graduate Student Researcher, Seoul National University
Sponsors
Plug Power, Incorporated, Latham, New York
U.S. Department of Defense Fuel Cell Program
National Fuel Cell Research Center